Installing the Switch
–The AC power cord can reach from the power outlet to the
•Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures.
•For 10/100 or 10/100/1000 ports, the cable length from a switch to an attached device cannot exceed 328 feet (100 meters).
•For cable lengths for small
•For cable lengths for XFP modules, see documentation that shipped with the module.
•Temperature around the switch does not exceed 122°F (50°C).
•Humidity around the switch does not exceed 95 percent.
•Altitude at the installation site is not greater than 10,000 feet.
Safety Warnings
Translations of these warning statements appear in the Regulatory Compliance and Safety Information for the Cisco ME
Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Statement 43
Warning Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe bodily injury and equipment damage. Statement 48
Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety:
•This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
•When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
•If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement 1006
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Cisco ME