Cisco Systems OL-11567-02 manual Workaround None at this time

Models: OL-11567-02

1 32
Download 32 pages 8.04 Kb
Page 20
Image 20
Workaround: None at this time.

Caveats

CSCsb07168—The AP1000 802.11a radio experiences a very low receive packet count when the receive RSSI is –75 dBm.

Workaround: None at this time.

CSCsb20269—On the WiSM, when the service VLAN is configured as one of the VLANs on a data port, it does not operate correctly.

Workaround: Do not configure the service VLAN as one of the VLANs on a data port.

CSCsb34149—Disabling or deleting a wireless LAN on which a large number of clients exists may not result in all clients being deleted. This generally occurs when several thousand clients are using the wireless LAN.

Workaround: Make sure that wireless LANs with a large number of clients associated are not deleted or disabled.

CSCsb38486—The Cisco Aironet 1500 Series Lightweight Outdoor Access Point Bridge CLI does not accept 10-character bridge group names.

Workaround: Use 9-character bridge group names.

CSCsb52557—Cisco access points do not connect to the 4400 series controller if the time is not set first.

Workaround: Set the time on the controller before allowing the access points to connect to the controller.

CSCsb55597—The access point’s output power may change after you modify a mandatory data rate. Workaround: None at this time.

CSCsb55937—VLAN-tagged large ICMP packets that need to be fragmented are not sent by Cisco Aironet 1000 series access points in direct-connection mode. Ping replies never come back when the access point sends requests to a gateway from a wireless client using large 1500-byte packets and with RADIUS override configured with any 1p tag. This condition exists for 4400 series controllers using direct-connect mode, with RADIUS override enabled, the override parameter set to 1p with any VLAN number, and Cisco Aironet 1000 series access points.

Workaround: None at this time.

CSCsb71060—Internal LAG errors occur when the management interface is changed from tagged to untagged.

Workaround: Leave the WiSM management interface as tagged or untagged.

CSCsb77595—When logging out from Telnet/SSH sessions, the session always prompts the user to save changes, even when no changes have been made.

Workaround: Ignore the prompt and exit as usual.

CSCsb85113—When users download the code image to WiSM using the CLI, associated access points are sometimes disconnected.

Workaround: Download new code images to the WiSM at times when there are no clients to be affected.

CSCsb88588—Incorrect power levels are reported for access points when the controller is set to country code SG.

Workaround: None for this release.

Release Notes for Cisco Wireless LAN Controllers and Lightweight Access Points for Release 3.2.171.6

20

OL-11567-02

 

 

Page 20
Image 20
Cisco Systems OL-11567-02 manual Workaround None at this time