Chapter 3 Product Hardware

Environmental Compliance

3.3.2 ONS 15252 Fan Unit Power and Grounding

The fan unit back panel has two power supply connectors. The far-right power connector (as viewed from the rear of the fan unit) is the primary source, and the far-left power connector is the secondary source. These power connectors are designated as 0V and -48V. A pair of grounding pins (M4 screws) is located next to each of the power connectors on the fan-unit back panel.

3.3.3 ONS 15201 SCU Power and Grounding

The ONS 15201 SCU chassis has two power supply connectors. The power supply located on the front of the ONS 15201 SCU chassis is labeled PS-2 (power supply two), and the power supply connector located on the backplane of the ONS 15201 SCU chassis is labeled PS-1 (power supply one)

(Figure 3-6). Lug-type grounding connectors located on the back of the chassis provide grounding. The power supplies convert AC to DC and provide a regulated -48 VDC to the ONS 15201 SCU.

3.4 Environmental Compliance

The ONS 15252 MCU is compliant with Network Element Building Systems (NEBS) Level 3 of Telcordia SR-3580 and applicable sections of Telcordia GR-63-CORE and Telcordia GR-1089-CORE. Additionally, the ONS 15200 system is compliant with ETS 300 019-1-1 (class 1.1), ETS 300 019-1-2 (class 2.3), and ETS 300 019-1-3 (class 3.1) for environmental requirements.

The ONS SCU 15201 is compliant with Network Element Building Systems (NEBS) Level 2 of Telcordia SR-3580 and applicable sections of Telcordia GR-63-CORE and Telcordia GR-1089-CORE. Additionally, the ONS 15200 system is compliant with ETS 300 019-1-1 (class 1.1), ETS 300 019-1-2 (class 2.3), and ETS 300 019-1-3 (class 3.1) for environmental requirements.

3.5 Electromagnetic Compatibility

The ONS 15200 system is compliant with Telcordia GR-1089-CORE and FCC Part 15 specifications for electromagnetic compatibility for NEBS Level 2 (SCU) and Level 3 (MCU). Additionally, the ONS 15200 system is complaint with ETS 300 386-1, classes 1 and 2 for electromagnetic compatibility.

3.6 Safety Specifications

This section provides ONS 15200 system laser and product safety specifications.

3.6.1 Laser Safety

The ONS 15200 system is compliant with IEC-60825-1, IEC 60825-2, and CFR 1040.10 requirements for laser safety.

Cisco ONS 15200 Product Description

3-10

78-13766-01

 

 

Page 36
Image 36
Cisco Systems ONS 15200 manual Environmental Compliance, Electromagnetic Compatibility, Safety Specifications