3.6.1 Controlling Alarm Display

78-11719-02 July 2001

Using Cisco Transport Controller 3

Figure 3-14

The Alarms tab showing two standing alarms and two cleared alarms

Alarms are displayed in one of five background colors, listed in Table 3-9,to communicate the alarm severity quickly.

Table 3-9

Alarm Colors

 

 

Color

Description

 

 

Red

Critical Alarm

 

 

Orange

Major Alarm

 

 

Yellow

Minor Alarm

 

 

Blue

Event Notification (not an alarm)

 

 

White

Cleared alarm or event

 

 

3.6.1 Controlling Alarm Display

You can control the display of alarms. Table 3-10shows the actions you can perform from the

Alarms tab.

Table 3-10

Alarm Display

 

 

 

Button

 

Action

 

 

Synchronize Alarms

Updates the alarm display; although CTC displays alarms in real time, the

 

 

Synchronize Alarms button allows you to verify the alarm display (particularly useful

 

 

during provisioning or troubleshooting)

 

 

Delete Cleared Alarms

Deletes alarms that have been cleared

 

 

 

Checkbox

 

 

 

 

AutoDelete Cleared Alarms

If checked, automatically deletes new cleared alarms

 

 

 

Cisco ONS 15327 User Documentation

3-25

Page 25
Image 25