Cisco Systems SMC-169 Verifying the Status of the External Reference Clock, Examples, SMC-187

Models: SMC-169

1 24
Download 24 pages 10.67 Kb
Page 19
Image 19
Verifying the Status of the External Reference Clock

Implementing NTP on Cisco IOS XR Software

How to Implement NTP on Cisco IOS XR Software

Verifying the Status of the External Reference Clock

This task explains how to verify the status of NTP components.

Note The commands can be entered in any order.

SUMMARY STEPS

1.show ntp associations [detail] [location node-id]

2.show ntp status [location node-id]

DETAILED STEPS

 

Command or Action

Purpose

Step 1

 

 

show ntp associations [detail] [location

Displays the status of NTP associations.

 

node-id]

 

 

Example:

 

 

RP/0/RP0/CPU0:router# show ntp associations

 

Step 2

 

 

show ntp status [location node-id]

Displays the status of NTP.

 

Example:

 

 

RP/0/RP0/CPU0:router# show ntp status

 

 

 

 

Examples

The following is sample output from the show ntp associations command:

RP/0/0/CPU0:router# show ntp associations

address

ref clock

st

when

poll reach

delay

offset

disp

+~127.127.1.1

127.127.1.1

5

5

1024

37

0.0

0.00

438.3

*~172.19.69.1

172.24.114.33

3

13

1024

1

2.0

67.16

0.0

* master (synced), # master (unsynced), + selected,

- candidate,

~ configured

The following is sample output from the show ntp status command:

RP/0/0/CPU0:router# show ntp status

Clock is synchronized, stratum 4, reference is 172.19.69.1

nominal freq is 1000.0000 Hz, actual freq is 999.9988 Hz, precision is 2**26 reference time is C54C131B.9EECF6CA (07:26:19.620 UTC Mon Nov 22 2004) clock offset is 66.3685 msec, root delay is 7.80 msec

root dispersion is 950.04 msec, peer dispersion is 3.38 msec

Cisco IOS XR System Management Configuration Guide

SMC-187

Page 19
Image 19
Cisco Systems SMC-169 Verifying the Status of the External Reference Clock, Examples, show ntp status location node-id