Tools
•
•
•14 AWG (2.08 mm2) cable with a minimum of three conductors rated for at least 140 ° F (60° C) (for
•Standard wire stripper
Step 1 Ensure that the
Step 2 At the rear of the router, check that the power switch on the power supply is in the OFF (0) position.
Step 3 Connect the
Step 4 Using a wire stripper, strip approximately 0.55 inch (14 mm) from the
Step 5 Insert the stripped end of the +48V lead all the way into the +48V lead receptacle and tighten the receptacle screw using a
Step 6 Make sure that the entire stripped end of each lead is inserted all the way into its receptacle. If any exposed wire at the stripped end of a lead is visible after inserting the lead into its receptacle, remove the lead from the receptacle, use the wire stripper to cut the stripped end of the lead, and repeat Step 4 and Step 5.
Step 7 After tightening the receptacle screws and nuts for the ground, +48V, and
Step 8 Install the
Step 9 Connect the ground wire, +48V lead, and
Caution Each
Warning | The illustration shows the DC power supply terminal block. Wire the DC power supply using the appropriate wire |
| terminations at the wiring end, as illustrated. The proper wiring sequence is ground to ground, positive to positive |
| (line to L), and negative to negative (neutral to N). Note that the ground wire should always be connected first and |
| disconnected last. Statement 61 |
|
|
17