Note If you are using a Cisco uBR7200-NPE-G1, you do not need an I/O controller module installed in the chassis. Use
the show version command (Router# show version) to determine the NPE that is installed in your router.
3. If the clock card ENABLED LED is off, verify that the card is securely installed in the chassis.
4. Always verify that the fans are operating. If the following message is displayed,
Queued messages:
%ENVM-1-SHUTDOWN: Environmental Monitor initiated shutdown
This message indicates that the system has detected an overtemperature condition or power out-of-tolerance condition
inside the chassis. The shutdown message could also indicate a faulty component or temperature sensor. Before the system

shuts down, use the show environment or show environment table command to display the internal chassis

environment.