Features

Table 2

Fax and Modem Transport Parameters (continued)

 

 

 

 

Port Used for Modem

Optimizes the performance of modem calls. If this

Checkbox checked

Calls

 

parameter is enabled and the parameters for voice

 

 

 

and fax calls are disabled, the port is configured to

 

 

 

accept only modem calls. Enabling this parameter

 

 

 

improves the performance of the port by reducing or

 

 

 

removing the switchover time required to move

 

 

 

from voice mode to modem mode. Enable this

 

 

 

parameter only if you are certain that a port will

 

 

 

handle modem calls only

 

 

 

 

Enabled Port Used for

Optimizes the performance of fax calls. If this

Checkbox checked

Fax Calls

 

parameter is enabled and the parameters for voice

 

 

 

and modem calls are disabled, the port is configured

 

 

 

to accept only fax calls. Enabling this parameter

 

 

 

improves the performance of the port by reducing or

 

 

 

removing the switchover time required to move

 

 

 

from voice mode to fax mode. Enable this

 

 

 

parameter only if you are certain that a port will

 

 

 

handlefax calls only

 

 

 

 

Named service event

NSE type attempts to standardize the transfer of

Non-IOS Gateway

(NSE) type

 

tones over real-time transport protocol (RTP). Two

 

 

 

NSE standards exist in Cisco products: one for

 

 

 

Cisco IOS gateways and one for non-Cisco IOS

 

 

 

gateways. The Catalyst 6500 Series Switch 8-port

 

 

 

T1/E1 PSTN interface module supports both

 

 

 

standards. You need to configure the right NSE type

 

 

 

based on the network setup. If the module needs to

 

 

 

talk to a Cisco IOS gateway (a VG200 or AS5300

 

 

 

for example), set this option to IOS Gateway. If the

 

 

 

gateways need to talk to other non-Cisco IOS

 

 

 

gateways (such as a WS-X6608-E1/T1, VG248, or

 

 

 

another WS-X6624-FXS), set this option to

 

 

 

non-IOS Gateway.

 

 

 

 

 

Hot Swapping

Hot swapping lets you remove and replace the 24-port FXS analog interface module while the system is operating. When the system detects that a module has been installed or removed, it automatically runs diagnostic and discovery routines, acknowledges the presence or absence of the module, and resumes system operation without any user intervention.

Power Management

Because the Catalyst 6500 series modules have different power requirements, certain switch configurations require more power than a single power supply can provide. Although the power management feature allows you to power all installed modules with two power supplies, redundancy is not supported in this configuration.

Catalyst 6500 Series 24-Port FXS Analog Interface Module Installation Note