(1)Connector Pin Configuration
No. | Signal | Function |
|
|
|
|
|
|
|
|
|
|
|
| Connector used: |
|
|
|
|
|
|
|
|
|
|
|
| ||||
1 | FG | Frame Ground |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| or equivalent | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
2 | DRAWER 1 | Drawer 1 drive signal |
|
|
|
|
|
|
|
|
|
|
|
| Applicable connector: |
3 | DRSW | Drawer switch input |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| equivalent | |||
4 | VDR | Drawer drive power supply |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
5 | DRAWER 2 | Drawer 2 drive signal |
|
| 6 |
| 1 |
|
|
|
| ||||
|
|
|
|
| |||||||||||
|
|
|
|
|
| ||||||||||
6 | GND | Common ground on circuits |
|
|
|
|
|
|
|
|
|
|
|
|
|
(2) | Electrical characteristics | |
| 1) | Driving voltage: 24 VDC |
| 2) | Driving current: Approx. 1A max. (shall not exceed 510 |
|
| ms.) |
| 3) | DRSW signal: Signal levels: “L” = 0 to 0.5 V, “H” = 3 to 5 V |
(3) | DRSW signal | |
| DRSW signal status can be tested with the DLE+EOT, |
1
2
3
5V VDR
GS+a, or GS+r command or |
at pin 34 on the parallel interface port. |
(4) Drive Circuit (printer side) |
VDR
4
5
6
CAUTION!
■No output is produced while printing.
■The cash drawers 1 and 2 cannot be driven simultaneously.
■A solenoid used for the cash drawer should be of 24 Ω or more. The output current should be kept at 1A or less; otherwise, breakdown or burning could occur.
3.4Precautions in Installing the PrinterThe printer must only be operated horizontally. Do not operate vertically or install on a wall.
Horizontal position | Vertical position |
CAUTION!
DO NOT use the printer under the following conditions.
■A state subject to vibration or unstable state.
■A state with this product slanted.
•Otherwise dropping may cause injury.
•Poor print quality may occur.
■A state where this product is installed vertically or sidelong.
• Malfunction, failure, or electric shock may result.
— 14 —