At the time of shipment, this partition is set to
1.Confirm that the power switch is OFF.
2.Open the printer cover.
3.Set the partition to each to the slot which meets the width of the paper roll used. When using the
4.Change the setting of paper width by reffering to the section 5.2, "Manual Setting of Memory Switch".
60mm
8058mm
mm
Partition
CAUTION!
When setting the partition to the slot for 58 mm or 60 mm paper roll, be sure not to set
it slanted.
3.6 Setting DIP SwitchThe DIP switch is present on the serial interface board.
Remove the board fixing screws, take out the interface board, and then set the DIP switch. The function of each switch is as shown below.
DIP switch
Interface board mounting screws
CAUTION!
When setting the DIP switch, DO NOT remove screws other than those for mounting the serial interface board.
Switch No. | Function | ON |
| OFF | InitialSettings | |
1 | Communication condition | DIP switch setting | Memory switch | OFF | ||
| setting method |
|
| setting |
| |
2 | Hand shake | XON/XOFF | DTR/DSR | OFF | ||
3 | Bit length | 7 bits | 8 bits | OFF | ||
4 | Parity check | With parity | None | OFF | ||
5 | Parity selection | Even parity | Odd parity | OFF | ||
6 |
|
|
|
|
| ON |
Baud rate selection | See Table below. |
|
|
| ||
7 |
|
|
| ON | ||
|
|
|
|
| ||
|
|
|
|
| ||
8 | INIT | Reset | Invalid | OFF |
Selecting baud rate
Baud Rate (bps) |
| Switch No. | |
6 |
| 7 | |
|
| ||
2400 | OFF |
| OFF |
4800 | ON |
| OFF |
9600 | OFF |
| ON |
19200 | ON |
| ON |
1200, 38400, 57600 and 115200 bps can also be selected by a command, etc.
— 15 —