Citizen CT-S4000DC user manual Partition for Paper Roll, Setting DIP Switch, Selecting baud rate

Models: CT-S4000 CT-S4000DC

1 136
Download 136 pages 38.17 Kb
Page 18
Image 18

3.5 Partition for Paper Roll

At the time of shipment, this partition is not installed.

1.Confirm that the power switch is OFF.

2.Open the printer cover.

3.Insert the partition into the slot and align it with the scale inside of the printer which meets the width of the paper roll used. When using the 80mm or 82.5mm wide paper roll, set the partition by using the accessory screw.

4.Change the setting of paper width by reffering to the section 5.2, "Manual Setting of Memory Switch".

CAUTION!

When using 112 paper roll, the partition is not used.

3.6 Setting DIP Switch

Partition

Scales

80mm 82.5mm

Partition

The DIP switch is present on the serial interface board.

The function of each switch is as shown below.

Interface board

DIP switch

 

mounting screws

 

CAUTION!

As for the setting of the serial interface, it gives priority to the setting of the memory switch rather than the DIP switch as the factory default.

Consult with the dealer where the printer was purchased when the change of the DIP switch setting is necessary.

Switch No.

Function

ON

 

OFF

InitialSettings

1

Communication condition

DIP switch setting

Memory switch

OFF

 

setting method

 

 

setting

 

2

Hand shake

XON/XOFF

DTR/DSR

OFF

3

Bit length

7 bits

8 bits

OFF

4

Parity check

With parity

None

OFF

5

Parity selection

Even parity

Odd parity

OFF

6

 

 

 

 

 

OFF

Baud rate selection

See Table below.

 

 

 

7

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

8

INIT

Reset

Invalid

OFF

Selecting baud rate

Baud Rate (bps)

 

Switch No.

6

 

7

 

 

2400

OFF

 

OFF

4800

ON

 

OFF

9600

OFF

 

ON

19200

ON

 

ON

38400, 57600 and 115200 bps can also be selected by a command, etc.