![6.DRAWER KICK-OUT CONNECTOR](/images/new-backgrounds/140044/14004483x1.webp)
6.DRAWER KICK-OUT CONNECTOR
(1)Drawer kick drive signal
The specified pulse will be output according to the specified pulse generating command (ESC <p>). When using the parallel interface. it will be possible to determine the condition of the drawer opening and closing switch from pin 34 of the interface connector. When using the serial interface. the switch condition may be determined by utilizing the peripheral equipment status sending command (ESC <u>).
(2)Electrical characteristics
Driving voltage | : DC 24V |
|
Driving current | : Maximum 1A (Should be less than 510 ms) | |
SW signal | : Signal level | 'L' = 0~0.5V |
|
| 'H' = 3~5V |
(3) Connector' s pin configuration
Connector pin | Signal name |
| Input/Output | Function |
1 | FG |
| – | Frame ground |
2 | L1 |
| Output | Drawer l |
3 | SW |
| Input | Drawer opening and closing switch (* l) |
4 | Vp |
| – | Driving power source |
5 | L2 |
| Output | Drawer 2 |
6 | GND |
| – | Signal gr ound |
Used connector |
|
| ||
Suitable connector | 285D- |
Note: It will not be possible to switch both drawer 1 and 2 to ON at the same time.
Note: Drawer operation will not be possible while the printer is printing.
Note: The duty should be kept to 20% or less.
Note: This connector is not to be used for connection to telephone lines.
30 | CITIZEN |