21
PlayLink is automatically active after a software update, and the PlayLink icon
willonlyappearontheCAN-BuscongurationscreenofaDeltaseriesdisc
player.
PlayLink can only select a single input per disc player. It is therefore
not designed for users who regularly play both CDs and DVDs
through dierent inputs from a single disc player. When PlayLink is
active the disc player will default to the same input every time play is
pressed, regardless of whether it is playing CD or DVD.
amp info Available for ampliers only, this screen displays the data provided by the
heatsink and AC Module temperature sensors (if available).
NOTE:isfeatureisonlyaccessiblewhenthetargetamplierison.
event log Reserved for ampliers, this feature is a protection circuitry event log which can
only be accessed when the target amplier is in standby. e protection circuit
shuts down the amplier or channel if it overheats or if its output could damage
your speakers. e event log details the circumstances surrounding the amp
going into protection and should be referred to in situations that require the
intervention of your dealer or Classé customer support.
e log can report the following events interpreted as follows:
• +ve slow blo trip & -ve slow blo trip — e average current has
reached the safe operating limit.
• +ve fast blo trip & -ve fast blo trip — e peak current has
reached the safe operating limit.
• over temperature trip — e unit temperature has reached the
safe operating limit.
• DC Output trip
e DC output level has reached the safe
operating limit.
• Communication failure — ere has been a loss of
communicationbetweentheamp’ssystemmonitoringsensors.
• AC line trip — (Does not apply to CA-D200, AMP2 or AMP5)
epowersupplyhasreachedthelimitsoftheamp’ssafe
operating range.
• Air intake lter — (Does not apply to CA-D200, AMP2 or
AMP5) e intake lter is constricting airow and should be
cleaned. is “event” is also triggered after every 2,000 hours of
operation, even if the sensors do not yet detect constricted airow.
e unit will continue to operate with its standby LED ashing
until the lter is checked and the unit reset by pressing and
holding the standby button for 3 seconds.
Events are rare and generally occur due to issues that are external to the amp.