Cleveland Range KEL-40-T, KEL-30 Recommended Floor Drain Detail, Assembly, Wire Connection, Water

Models: KEL-60 KEL-60-TSH KEL-60-T KEL-25 KEL-25-T KEL-40 KEL-40-T KEL-80-T KEL-100-T KEL-60-SH KEL-30

1 29
Download 29 pages 54.97 Kb
Page 4
Image 4
RECOMMENDED FLOOR DRAIN DETAIL

RECOMMENDED FLOOR DRAIN DETAIL

RECOMMENDED

FLOOR

FLOOR SLOPE

DRAIN

 

1" IN 4'

4" MINIMUM,

PIPE DRAIN

6" RECOMMENDED

RECOMMENDED

 

MINIMUM VALVE

 

SIZE PLUS 1"

ASSEMBLY

 

FLANGED

ASSEMBLY FOOT (5" DIA)

(3) 7/16" DIA.

WIRE CONNECTION 3 1/8"Stationary ModelsTilting Models HOLES

Flanged Foot Detail

Position the kettle in it's permanent location, and level the kettle by turning the adjustable flanged feet. Once positioned and leveled, permanently secure the kettle's flanged feet to the floor using 5/16" lag bolts and floor anchors (supplied by the installer). There are three bolts required to secure each of the flanged feet.

WIRE CONNECTION

Install in accordance with local codes and/or the National Electric Code ANSI/NFPA No. 70-1990 (USA) or the Canadian Electric Code CSA Standard C22.1 (Canada). A separate fused disconnect switch must be supplied and installed. The kettle must be electrically grounded by the installer.

The electrical supply must match the power requirements specified on the kettle's rating plate. The copper wiring must be adequate to carry the required current at the rated voltage.

Note: Maximum voltage for LVD (low voltage directive for Europe) to be 440 volts for CE marked appliances.

THREE

BLACK

 

BLUE

 

RED

 

SINGLE

BLACK

BLUE

RED

 

 

 

 

 

 

 

 

 

 

 

 

 

PHASE

 

 

 

 

 

 

 

PHASE

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

YELLOW

 

 

 

 

 

 

 

YELLOW

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

L2

L3

 

 

L1

 

L2

The kettle is wired for 3-phase operation at the factory. For single phase operation, rewire the terminal block to that shown in the above diagram.

Note: Ensure main power is turned off before connecting wires.

Stationary Models

Remove the screws securing the dome-shaped service cover underneath the kettle and remove the cover. A wiring diagram is affixed to the inside of cover. Fasten permanent copper wiring to the three-connection terminal block, Be sure to connect ground wire to the separate ground terminal connector (ground lug). Slide the cover's slot over the wiring and secure the cover to kettle with the screws.

Tilting Models

First remove the handwheel by loosening the allen screw. Then remove the two screws at the front and rear of the console cover and remove the cover. A wiring diagram is affixed to the underside of the console cover. Feed permanent copper wiring through the cut-out in the bottom of the console, and fasten to the three-connection terminal block. Be sure to connect the ground terminal connector (ground lug). Replace the console cover and handwheel.

WATER

The sealed jacket of the electric kettle is precharged with the correct amount of a water- based formula, and therefore, no water connection is required to the kettle jacket. The kettle can be equipped with optional hot and cold water taps, the taps require 1/2" copper tubing as supply lines.

Page 4
Image 4
Cleveland Range KEL-40-T, KEL-30 manual Recommended Floor Drain Detail, Assembly, Wire Connection, Water, Stationary Models