4.3. Optional Drain Pump—INSTALLATIONINSTRUCTIONS

Parts Manual

4.3. Optional Drain Pump—INSTALLATIONINSTRUCTIONS

1.Start by removing the existing drain hose from the Drain Valve as shown in Figure 1.

Remove From Scrap Tray

Remove

Manual background From Wash Tank

Figure 1

2.Locate the white and purple wires that are safe-ended and tie-wrapped at the top of the Drain Pump compartment. Bring these wires out so they can be connected after mounting the Drain Pump.

3.Connect the 3-inch long pump inlet drain hose to the Drain Valve and mount the Drain Pump using the nuts and washers provided with the kit as shown in Figure 2.

Remove this cover to make wire connections.

White wire

Purple wire

Tighten this hose clamp over Drain Valve.

Drain hose must elevate 12 to 16 inches before dropping to drain.

3-inch pump inlet drain hose.

Figure 2

4.Remove the terminal cover and connect the white and purple wires to the two white wires from the pump. Replace the cover.