Operation
3.Operation
3.1. Initial Setup
3.1.1. Dema Valve and Dema Flow Disc (New Models).
New Dema Valve made of stainless steel is more compatible with various water conditions. Dema Flow Disc has been placed on the exit side of the water valve. The Flow Disc reduces pressure to the standard recommended 20 PSI.
3.1.2. Rinse Pressure Regulator (Old Models Prior January 2008).
The
1.Close the door on the machine.
2.Turn the Power switch to the "ON" position.
3.While holding the “FILL”
3.1.3.Rinse and Wash Temperatures
1.Turn the Power switch to the "ON" position.
2.After the machine has warmed up for about
3.1.4.Post Instructions
1.Install wall chart and instruct machine operator on proper cleaning and operation of the
3.2.Startup Procedures
1.Open the door of the machine and check that the scrap screen is in place, and that the spray arms and end plugs are secure.
2.Close the door of the machine and turn the Power switch to the "ON" position.
3.Hold the fill button about 25 seconds or until the water overflows into the scrap tray.
4.Once the water is filled to the proper level, press the rocker switch marked “START”
– the machine will automatically begin its cycle.
5.Check machine’s operating temperatures — Adjust if necessary. See section 3.1.3 Rinse and Wash Temperatures.
6.At the end of the wash period, drain the machine by pushing the rocker switch marked “DRAIN”. Clean the wash tank screen and scrap tray screen. Remove and clean the spray arms. (See wall chart instructions).
3Rinse cycle temperature must be observed during a rinse cycle while the machine is in operation.
MODEL | Page 11 |