CMA Dishmachines CMA-180UC NOVA Detergent and Rinse Dispenser Optional1, Wire Colors, Function

Models: CMA-180UC

1 25
Download 25 pages 24.95 Kb
Page 7
Image 7
2.2.3. NOVA Detergent and Rinse Dispenser (Optional)1.

2.2.3. NOVA Detergent and Rinse Dispenser (Optional)1.

The NOVA Detergent and Rinse Dispenser has its own reference manual. Familiarize yourself with the dispenser’s reference manual before proceeding with installation.

1.The NOVA dispenser is pre-wired with a multi-conductor electrical cable that is to be run through a conduit to the power block inside the control panel drawer. Use a ½” watertight conduit meeting all local and national codes. A conduit fitting is present on the bottom of the dispenser where the power cable exits. A mounting plate to receive the ½” conduit is provided on the top right-hand corner (facing the back) of the machine.

i.Run an appropriate length of ½” conduit from your dispenser to the mounting plate where it will be secured. The conduit needs to be of sufficient length and flexibility to permit the machine to be moved for cleaning without having to disconnect any wiring.

ii.Run your dispenser wires through the conduit and through the enclosed area across the top of the machine and then feed them through the access hole provided in the back of the control panel drawer.

iii.With the machine’s power “OFF”, connect your detergent and rinse dispenser wires to the power block supplied and labeled (“DISPENSER 110V - 3 AMPS MAX”) inside the control panel drawer. The table that follows lists the function of each conductor of the multi-conductor electrical cable.

Wire Colors

Circuit Voltage

Function

Gray/Violet

90

VAC-130 VAC 50/60 Hz

Main AC Power

Black

90 VAC-130 VAC 50/60 Hz

Main AC Power

Brown

No Connection. Insulate this wire!

This wire is LIVE!

Yellow

90

VAC-130 VAC 50/60 Hz

Detergent Signal

White/Yellow

90

VAC-130 VAC 50/60 Hz

Detergent Signal

Violet

90

VAC -130 VAC 50/60 Hz

Rinse Signal

White/Violet

90

VAC -130 VAC 50/60 Hz

Rinse Signal

The individual conductors need to be connected as shown in Figure 2.2.3 and as described on next page.

1All electrical and plumbing connections must be made by a qualified person who will comply with all available Federal, State, and Local Health, Electrical, Plumbing and Safety codes