Overcharging the batteries is not possible.

??Charging station is ready.

?red LED flashes in 5 sec rythm

??Insert Compur Ex plus to the charging slot. ??Normal charging

?red LED is on continuously, green LED is off.

If the detector is not inserted correctly, red LED will flash.

??If battery is approx. 60 % full, both red and green LED’s are on continously up to 100 % charge.

??If batteries are completely empty, the charging time is approx. 4 hours for the standard battery and approx. 14 hours for the longterm battery.

?When fully charged, green LED is continuously on, red LED is off.

The charging station will automatically switch to conservation mode to avoid over- charging the battery.

The 4-slot charger has one fast charging slot for the longterm battery. This reduces the charging time by half.

Overcharging the batteries is not possible.

3.1 Battery Exchange

The batteries of the Compur Ex plus can be easily exchanged, thus allowing continuous operation of the instrument.

Do not shorten battery contacts !

Inserting the battery

??Make sure the detector is switched off. ??Insert the battery into the detector until

the latches snap.

Removing the battery

??Make sure the detector is switched off. ??On both sides of the detector you will find

dots marked with “Press”. When pressing these points, battery can be pulled out of the instrument.

%UEG/LEL

Methan

OFF

TEST

ON

Fct

Cal

Ex plus

The batteries may be exchanged in hazardous areas !