Connect Tech Inc. FreeForm/Express S6 - PCIe Spartan-6 FMC Carrier User Manual

Function

Hot Swap

 

 

 

 

 

When the is being configured, FPGA I/Os will be pulled

 

 

high with weak internal pull-ups

 

 

 

 

 

 

 

 

 

 

 

Location

J2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

1x2 0.100” jumper block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pinout

 

 

 

 

 

 

 

 

 

 

 

Position

 

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

1-2

 

 

I/Os have pullups

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

I/Os are floating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

Floating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function

 

FMC JTAG Bypass

 

 

 

 

 

 

 

 

 

Selects either whether or not to include the FMC module

 

 

 

in the JTA chain

 

 

 

 

 

 

 

 

 

 

 

 

Location

 

J3

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

2x2 0.100” jumper block

 

 

 

 

 

 

 

 

 

 

 

 

Pinout

 

 

 

 

 

 

 

 

 

 

 

Position

 

Description

 

 

 

 

 

1-3

 

TDI to FMC

 

 

 

 

 

 

 

 

 

 

 

 

 

2-4

 

TDO from FMC

 

 

 

 

 

 

 

 

 

 

 

 

 

3-4

 

Bypass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

Not applicable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Default

 

Bypass

 

 

 

 

 

 

 

 

 

 

 

 

Ethernet

Description

Two 10/100/1000 Ethernet ports are connected to the FPGA, via two separate RGMII capable Ethernet physical layer devices (PHYs). The FPGA logic resources are used to implement the Ethernet media access controller (MAC).

Connector & LEDs

Function

Ethernet

 

 

 

 

Location

P6A, P6B

 

 

 

 

Type

2x5 2mm header

 

 

MLE TSHSM-205-D-06-G-V-L (or equivalent)

 

Revision 0.01

13

Page 13
Image 13
Connect Tech CTIM-00060 user manual Ethernet, Connector & LEDs