EdgeAccess® Universal Chassis System

6.2WWDM Model Specifications

The Model 6002/3/4 is available in a variety of user-specified wavelengths and loss budget configurations. All end-to-end loss calculations were figured at maximum loss values.

Note: Actual attenuation loss values should be used when computing final loss budgets.

Basic channel features and wavelengths are defined in Tables 2 through 4. The model type options for fused or filtered fiber applications are noted.

6.2.1 Unidirectional Two Channel WDM

The Model 6002 is a two channel unidirectional module with various wavelength configurations. Table 2 shows current available model options.

Table 2. Unidirectional Two Channel WDM Chart

MODEL

MODEL

WAVELENGTH

END-TO-END

DIRECTIVITY

ISOLATION

NUMBER

TYPE

Nanometers (nm)

LOSS (dB)

(dB)

(dB)

 

 

 

 

 

 

 

6002

FUSED

1310 / 1550

2.0

(1310)

55

≥25

 

*

 

2.0

(1550)

 

 

 

 

 

 

 

 

 

6002

FUSED

1480 / 1550

1.7

(1480)

55

≥25

 

*

 

1.7

(1550)

 

 

 

 

 

 

 

 

 

6002

FILTER

1543 / 1557

3.0

(1543)

55

≥25

 

 

 

2.0

(1557)

 

 

 

 

 

 

 

 

 

*Fused type WDMs have broad operating passbands, typically at ±15nm.

Note: This enables the 6002 models to be used over a larger wavelength range.

6-2

6002/6003/6004 WWDM Users Manual

Page 24
Image 24
Continental Automated Buildings Association 6002 user manual Wwdm Model Specifications, Unidirectional Two Channel WDM