Cornelius 326142000 Turning on Electrical Power to Unit, Turning on CO2 Supply to Unit

Models: 326142000

1 87
Download 87 pages 28.2 Kb
Page 19
Image 19

TURNING ON ELECTRICAL POWER TO UNIT

Turn on electrical power to Unit. Operational status of Unit is now being displayed as fault messages on control panel message display. The following fault messages will be continuously displayed at 2-second intervals until necessary operation requirements are satisfied.

‘‘OFF 1’’ (Beater Motor No. 1 not operating) ‘‘OFF 2’’ (Beater Motor No. 2 not operating) ‘‘H2O OUT’’ (No water supply to Unit)

‘‘CO2 OUT’’ (No CO2 gas supply to Unit)

‘‘SYRUP 1’’ (No syrup supply to Unit No. 1 syrup system) ‘‘SYRUP 2’’ (No syrup supply to Unit No. 2 syrup system)

TURNING ON CO2 SUPPLY TO UNIT

1.Open CO2 cylinder valve slightly to allow lines to slowly fill with gas, then open valve fully to back seat valve. Back-seating valve prevents leakage around valve shaft.

IMPORTANT: If bag-n-box syrup supply system will be connected to Unit instead of soft drink tanks, primary CO2 regulator (see Figure 2) must be adjusted no higher than 80-psi maximum.

2.Adjust primary CO2 regulator (see Figure 2) by turning regulator adjusting screw to the right (clockwise) until regulator pressure reads 80 to 100-psig. OUT OF CO2 warning light on control panel message display should have gone out.

3.Pull up on product blender tanks relief valves to purge air from tanks.

4.Remove Unit lower access panel as instructed for access to carbonator secondary CO2 regulators (see Figures 2 and 6).

5.Check product blender tanks secondary CO2 regulators with 60-psi gages for pressure setting which should be set at 30-psi for best textured product. If further adjustment is necessary, adjust as instructed.

IMPORTANT: Carbonator secondary CO2 regulator must be adjusted 25-psi higher or more above product blender tanks secondary CO2 regulators pressure settings. Carbonated water and syrup pressures must be able to overcome and vent product blender tanks head pressures while tanks are filling with carbonated water and syrup. Carbonator tank secondary CO2 regulator not adjusted high enough will cause decreased flow of carbonated water into blender tanks which will increase brix of dispensed product.

6.Adjust carbonator secondary CO2 regulator, with 100-psi gage, by turning regulator adjusting screw to the right (clockwise) until gage reads 60-psi.

7.Pull up on carbonator tank relief valve plastic cover to purge air from tank.

TURNING ON PLAIN WATER SUPPLY TO UNIT

Open plain water inlet supply line shutoff valve. Check for water leaks and tighten or repair if evident. ‘‘H2O OUT’’ fault message should have gone out but ‘‘BM 1 OFF’’, ‘‘BM 2 OFF’’, ‘‘SYRUP 1’’, and ‘‘SYRUP 2’’ fault messages will continue to be displayed.

CONNECTING SOFT DRINK TANKS TO UNIT SYRUP SYSTEMS

IMPORTANT: Product shutoff valves, located in lines leading from product blender tanks to freeze cylinders (see Figure 2 and 6), must be closed at this time. Closing valves prevents product from filling freeze cylinders while checking BRIX of product in product blender tanks.

1.Close product shutoff valves, located in lines leading from product blender tanks to freeze cylinders, to prevent product from entering cylinders.

326142000