TROUBLESHOOTING

TROUBLESHOOTING

IMPORTANT: Only qualified Personnel should service internal components or electrical wiring.

WARNING: If repairs are to be made to a syrup system, disconnect syrup supply from the applicable syrup system, then relieve the system pressure before proceeding. If repairs are to be made to the CO2 system, stop dispensing, shut off the CO2 supply, then relieve the

system pressure before proceeding. If repairs are to be made to the unit electrical system, make sure electrical power is disconnected from the unit before proceeding.

Should your unit fail to operate properly, check that there is power to the unit and that the hopper con- tains ice. If the unit does not dispense, check the following chart under the appropriate symptoms to aid in locating the defect.

Trouble

 

Probable Cause

 

Remedy

BLOWN FUSE OR CIRCUIT

A.

Short circuit in electrical wiring.

A.

Repair electrical wiring.

BREAKER

 

 

 

 

 

B.

Inoperative 24 VAC

B.

Replace transformer.

 

 

transformer.

 

 

 

C.

Inoperative agitator motor.

C.

Replace agitator motor.

 

D.

Shorted motor.

D.

Replace Agitator Auger motor.

 

 

 

 

 

AGITATOR DOES NOT TURN,

A.

No electrical power.

A.

Restore electrical power.

AUGER DOES NOT TURN.

 

 

 

 

 

B.

Bent depressor plate (does not

B.

Replace depressor plate.

 

 

actuate switch).

 

 

 

C.

Inoperative dispensing switch.

C.

Replace dispensing switch.

 

D.

Inoperative interlocks, lids not

D.

Replace interlocks.

 

 

closed.

 

 

 

E.

Inoperative timer board.

E.

Replace timer board.

 

F.

Inoperative 24 VAC

F.

Replace transformer.

 

 

transformer.

 

 

 

 

 

 

 

ICE DISPENSES

A.

Stuck or bent depressor plate

A.

Replace depressor plate.

CONTINUOUSLY.

 

(does not release switch).

 

 

 

B.

Inoperative dispensing switch.

B.

Replace dispensing switch.

 

C.

Improper switch installation.

C.

Correct switch installation.

 

D.

Inoperative timer board.

D.

Replace timer board.

 

 

 

 

 

SLUSHY ICE. WATER IN

A.

Blocked drain.

A.

Unplug and flush out the drain.

HOPPER.

 

 

 

 

B.Unit not sitting level.

C.Poor ice quality due to water quality or icemaker problems.

B.Level the unit.

C.Install water filter system. For icemaker problems, consult icemaker manual.

 

D. Improper use of flaked ice.

D. Use correct ice.

AGITATOR TURNS, AUGER

A.

Inoperative auger motor.

A.

Replace auger motor.

DOES NOT TURN.

 

 

 

 

 

B.

Inoperative or improper setting

B.

Replace speed control or

 

 

of speed control.

 

re–adjust speed control.

 

 

 

 

 

19

620918702

Page 22