Trouble |
| Probable Cause |
| Remedy |
AGITATOR TURNS, AUGER | C. | Inoperative rectifier. | C. | Replace rectifier. |
DOES NOT TURN (CONT’D) |
|
|
|
|
| D. | Ice jam. | D. | Clear ice jam. |
| E. | Inoperative timer board. | E. | Replace timer board. |
|
|
|
|
|
AUGER TURNS, AGITATOR | A. | Inoperative agitator motor. | A. | Replace agitator motor. |
DOES NOT. |
|
|
|
|
| B. | Inoperative motor capacitor. | B. | Replace motor capacitor. |
| C. | Inoperative timer board. | C. | Replace timer board. |
|
|
|
| |
BEVERAGES DONOT | A. | No 24 volts to dispensing | A. Make sure unit is connected to | |
DISPENSE |
| valves. |
| electrical power. Check 24 VAC |
|
|
|
| transformer. |
| B. | No CO2 pressure. | B. | Check CO2 regulator. Check CO2 |
|
|
|
| tank pressure. |
|
|
|
|
|
BEVERAGES TOO SWEET. | A. | Carbonator not operating. | A. | Consult carbonator manual. |
B.No CO2 pressure in carbonator.
C.Dispensing valve brix requires
B.Check CO2 regulator. Check CO2 tank pressure.
C.Refer to dispensing valve manufacturer for brix adjustment instructions.
BEVERAGES NOT SWEET | A. Depleted syrup supply. | A. Replenish syrup supply. |
ENOUGH |
|
|
B.Dispensing valve brix requires
B.Refer to dispensing valve manufacturer for brix adjustment instructions.
BEVERAGES NOT COLD. | A. Unit standing with no ice in it’s A. Replenish ice supply. |
| hopper. |
|
|
NOTE: Contact your local syrup or beverage equipment distributor for additional information and trouble shooting of your beverage system.