INSTALLATION INSTRUCTIONS
COUNTER HEIGHT | DISPENSER | AVAILABLE SPACE | USE KIT NO. |
(INCHES) | DEPTH | BELOW DISPENSER |
|
| (INCHES | (INCHES) |
|
|
|
|
|
30 | 29 | 1 | CONSULT FACTORY |
|
|
|
|
31 | 29 | 2 | CONSULT FACTORY |
|
|
|
|
32 | 29 | 3 | 620517502 |
|
|
| AND |
|
|
| 629087406 |
|
|
|
|
33 | 29 | 4 | 629087406 |
|
|
|
|
34 | 29 | 5 | 629087406 |
|
|
|
|
29 | 629087412 | ||
|
|
| AND |
|
|
| 620517502 |
|
|
|
|
35 | 29 | 6 | 629087412 |
|
|
|
|
36 | 29 | 7 | 629087412 |
|
|
|
|
COUNTERTOP INSTALLATION
IMPORTANT: It is the responsibility of the installer to ensure that the drains from the dispensing equipment is installed and maintained according to Federal, State, and local laws.
1.Locate the dispenser indoors on a level countertop.
The dispenser must be sealed to the countertop. The MOUNTING TEMPLATE (see Figure 1) indicates the opening that must be cut in the countertop. Locate the desired position for the dispenser, then mark the outline dimension on the countertop using the dimensions given or use the full size template enclosed.
Apply a continuous bead of NSF International (NSF) listed silastic sealant (Dow 732 or equivalent) approxi- mately 1/4 inch inside the dispenser outline dimensions and around all openings. Position the dispenser on the countertop within the outline dimensions. All excess sealant must be wiped away immediately.
2.The drain tube is routed through the large opening in the bottom of the dispenser. See the MOUNTING TEMPLATE (see Figure 1) for locating the required clearance hole in the countertop for these utility lines. The power cord is routed through hole in the side of the dispenser electrical control box.
3.SINK DRAIN ASSEMBLY: Connect the drain tube to an open drain. Additional drain tubing is provided with the Dispenser. The drain tube must continuously pitch downword and contain no “traps” or improper drain- age will result.
A.Use
B.To assure proper drainage, do not allow a “trap” to form in the drain line. Be sure drain line runs flat with bottom of the dispenser.
IMPORTANT: This dispenser must be installed with adequate backflow protection to comply with Federal, State, and Local Codes.
4.Clean the hopper interior (See CLEANING INSTRUCTIONS).
5.Connect dispenser power cord to 120 VAC 60 HZ
5 | 620918702 |