Cornelius SID851A/250S-BC, SID851W/250S-BC manual 90914

Models: SID851W/250S-BC SID851W/250S-B SID851W/250S SID851A/250S-BC SID851A/250S-B SID851A/250S

1 40
Download 40 pages 39.02 Kb
Page 22
Image 22

1. TOTALLY INOPERATIVE

YES

POWER

NO

PRESENT AT

 

REAR JUNCTION

 

 

BOX?

 

 

 

CHECK FOR LOOSE CONNECTION

OR BROKEN WIRE INSIDE UNIT.

IS LINE

NOVOLTAGE

WITHIN ± 10% OF

NAMEPLATE

VOLTAGE?

YES

1.CHECK FOR SHORT CIRCUIT IN WIRING INSIDE UNIT.

2.CHECK COMPONENTS FOR SHORT CIRCUIT OR GROUNDED WIRING.

IS

LINE VOLTAGE

HIGH OR

LOW?

IS

YESSUPPLY FUSE

BLOWN (OR C/B

TRIPPED)?

NO

CHECK FOR LOOSE CONNECTION

OR BROKEN WIRE IN SUPPLY

WIRING OF UNIT.

IS

YESFUSE OR C/B

SIZE PROPER?

NO

REPLACE WITH CORRECT

SIZE DEVICE.

LOW

HIGH

INSTALL BUCKING TRANSFORMER

TO REDUCE LINE VOLTAGE.

IS

YESOTHER EQUIP. ON SAME CIRCUIT?

NO

1.REMOVE ALL OTHER EQUIPMENT FROM ICE MAKER CIRCUIT.

2.INSTALL NEW DEDICATED CIRCUIT FOR ICE MAKER.

1.CHECK FOR LOOSE OR CORRODED CON- NECTION IN SUPPLY WIRING.

2.CHECK SUPPLY WIRING FOR UNDER- SIZED WIRE, AND REPLACE.

3.INSTALL BOOSTING TRANSFORMER TO RAISE LINE VOLTAGE.

19

90914

Page 22
Image 22
Cornelius SID851A/250S-BC, SID851W/250S-BC manual 90914