4. BEVERAGE SYSTEM PROBLEM

IS

ONE OR MORE

FAUCETS

INOPERATIVE?

NO

IS

BEVERAGE

COLD?

YES

IS

BEVERAGE

PROPERLY

CARBONATED?

YES

IS

BEVERAGE

TOO SWEET?

NO

IS

BEVERAGE

TOO WATERY?

YES

NO

NO

YES

YES

1.CHECK WIRING CONNECTIONS TO IN- OPERATIVE FAUCETS.

2.REPLACE INOPERATIVE FAUCETS.

3.CHECK WIRING CONNECTIONS FROM 24V. TRANSFORMER.

4.CHECK 24V. TRANSFORMER.

1.CHECK REMOTE COOLING SYSTEM. (-B MODELS)

2.CHECK FOR ICE ON COLD PLATE. (-BC MODELS)

3.CHECK CO2 PRESSURE.

4.CHECK CARBONATOR.

1.CHECK WATER SUPPLY PRESSURE.

2.CHECK SUPPLY FILTER.

3.CHECK CARBONATOR.

4.CHECK FAUCET BRIX.

1.CHECK IF SYRUP TANK IS EMPTY.

2.CHECK CO2 PRESSURE.

3.CHECK FAUCET BRIX.

NO