SYSTEM DETAILS

UF-1 and UFB-1 Valves Training Manual

5.Remove valve from mounting block by pushing locking tab to left and push down on top plate of block. .

Locking tab

Locking tab

 

 

 

 

Mounting

6. Remove water screw and lever (if it is installed

screw

 

on the valve).

Water

 

 

lever

 

 

7.Remove nozzle – turn left ¼ turn.

8.Remove diffuser assembly.

Note: The diffuser must be cleaned daily. Do not use bleach, do not use detergent, do not put in dishwasher. Use lukewarm water or soak in carbonated water.

9.Remove bottom plate by disengaging side tabs.

Manual backgroundTabs

Retainer wire

10.Remove U-shaped retainer wire from back of valve.

11.Grasp flow control module assembly and pull up.

Note: O-rings on bottom of inlets and outlets.

O-rings

- 10 -

© 1999-2005, IMI Cornelius Inc.