15. Carefully remove banjo lever springs.

UF-1 and UFB-1 Valves Training Manual

Flow rate & date code

12. Note that the flow rate (1 ½ - 3, 3 – 4 ½ or 1 ½ - 3 juice) and date code are printed on the retainer plate.

13.To disassemble the flow control: Remove screws and pull retainer forward. Remove top flow con- trol subassemblies exposing flow controls.

Note the difference between high flow and ultra flow valves.

Note: Top Flow control is an assembly and cannot be dissas- embled.

Concentrate valve sleeve has one hole

Ultra Flow

 

notched

 

piston for

Syrup valve sleeve

water

 

has six holes

14.Pop off solenoid cover. Remove solenoid assembly from valve body by prying with screwdriver.

Note: Check plunger for corrosion and dirt – replace as necessary.

Solenoid

plunger

Pry here Manual backgroundManual background

Solenoid cover

Spring

15. Carefully remove banjo lever springs.