SLR • SLC • SLD OPERATOR INSTALLATION GUIDE

TERMINAL CONNECTION DESCRIPTIONS

TERMINALS

FUNCTION

DESCRIPTION OF FUNCTION

24VAC

24VAC

Provides 24Volt AC power for accessories.

24VAC N

 

Note: DC models will NOT have 24Volt AC power available.

24VDC+

24VDC

Provides 24Volt DC power for accessories.

24VDC- COMM.

 

 

1 & 4

OPEN

Opens the operator. Several accessories such as button stations, keypads, trans-

 

 

mitters and card readers can be wired to open.

3 & 4

CLOSE

Closes the operator. Use caution when wiring accessories to these terminals. The

 

 

gate must be clearly visible from the location of any accessories wired to

 

 

close.

4 & 5

SINGLE-BUTTON

Performs the single-button function which will alternate between open and close or

 

 

open, stop and close - depending on dip switch #3. (See page 9 for details.)

2 & 4

STOP

Stops the operator. If no stop button is used, a jumper is required across 2&4.

4 & 6

REVERSE

This function will cause a reversal when the gate is traveling closed and will travel

 

 

back to the fully open position. Loop detectors are often wired for reverse.

4 & 50

OPEN

This function works only while the operator is opening. Any signal to this function

 

OBSTRUCTION

will cause the gate to stop, reverse a short distance, and then stop again. At this

 

 

time the auto close timer is disabled, and a renewed input will be required to start

 

 

the gate again. Should the gate be restarted and the signal occur again prior to

 

 

reaching a limit, the gate will stop again, and this time will sound the emergency

 

 

alarm and lock out.

4

& 51

CLOSE

 

 

OBSTRUCTION

4

& 11

SHADOW/HOLD

This function works exactly like the OPEN OBSTRUCTION, except that it will only work in the closing direction.

This function will keep the gate in its fully open position while the signal is present. This is typically used with a loop and loop detector to keep a large swing gate open while vehicular traffic is passing through.

24VDC+ & 60

RUN/PRE-START

A 24Volt DC device such as a strobe light or alarm can be wired to these terminals.

 

 

Depending on dip switch #2, these devices will either begin three seconds before

 

 

the operator starts, or only while the motor is running. (See page 9 for details.)

You must follow all required safety precautions and instructions at all times. Review the safety brochure included with the operator. If any pages are missing or unreadable, contact OSCO at 1-800-333-1717 to request additional copies.

Never connect a button station within reach of the gate or on the side of the gate operator.

Do not adjust the circuit board current sensing feature too high. It should be adjusted high enough to keep the gate from falsely triggering the sensing, but no higher than necessary for the gate to operate. Do not defeat the purpose of this function!