Cosco SLC, SLR, SLD manual Slr, Slc & Sld, PAD Mounting Instructions for Models

Models: SLR SLC SLD

1 40
Download 40 pages 23.52 Kb
Page 5
Image 5

SLR • SLC • SLD OPERATOR INSTALLATION GUIDE

PAD MOUNTING INSTRUCTIONS FOR MODELS

SLR, SLC & SLD

Before installing, make sure the gate rolls or slides freely, and that all exposed rollers are properly covered. The gate must be covered with fabric with openings no larger than 2 1/4” in size, to a minimum height of 48 inches above ground level. On picket-style gates, if pickets are spaced less than 2 1/4” apart, mesh is optional.

To assemble the drive chain and gate brackets, refer to Page 6. Make sure that the chain sag does not exceed recommended sizes and that the chain does not come into contact with the moving parts of the gate or ground.

A SEPARATE PEDESTRIAN GATE IS REQUIRED

FOR ALL PEDESTRIAN TRAFFIC.

THIS GATE MUST BE A MINIMUM DISTANCE

OF SEVEN (7) FEET FROM THE

VEHICULAR GATE AND GATE OPERATOR.

- 5 -

8-04-5

Page 5
Image 5
Cosco SLC, SLR, SLD manual Slr, Slc & Sld, PAD Mounting Instructions for Models