CONTROL PANEL ACCESS
HI LO
| FAN SPEED | VALVE |
|
|
|
|
|
| CONTROL |
|
|
|
|
|
|
|
|
| FAN SPEED |
|
HI | LO |
| PIEZO | HI | LO | PIEZO |
FLAME COMFORT | O FF |
| IGNITOR | |||
OFF |
|
|
| |||
|
|
|
|
|
FIGURE 6: CONTROL PANEL
The control panel is accessed through the front door of the Bayvue DV as shown in FIGURE 6. The control panel has controls that adjust the blower fan speed, adjusts the burning setting, includes the burning control, and the piezoelectric igniter control.
HEARTH REQUIREMENTS
When the Bayvue DV is to be installed directly on carpeting, combustible tile or other combustible material other than wood flooring, the carpet or combustible material must be covered first. Other than wood flooring, the floor must be covered with metal,
VALVE ASSEMBLY REMOVAL
From time to time, it may be necessary to remove the valve assembly. This assembly includes the SIT 820 control valve, the base mounting plate for the burner assembly, the pilot system, the three burner spud (a spud is a removable cap or plug) orifice assemblies, and miscellaneous tubing. If it is ever necessary to remove the valve assembly, take care not to damage any parts. Further, this system, once removed, should be inspected by a certified professional before the valve assembly is reinstalled. The following steps should be followed to ensure no damage occurs in removing the valve assembly. To reinstall the valve assembly, reverse the steps as listed during the installation procedure.
STEP 1 Remove the control panel front access door by removing the screw hinge pins at the bottom of the door.
STEP 2 Remove by pulling the rheostat knob off. Remove the four screws holding the control panel front bezel in place and remove the bezel plate. Disconnect the piezoelectric igniter’s wire from the igniter.
STEP 3 Remove the four screws holding the control panel support brackets.
STEP 4 Remove the two screws holding the heat shield that is directly above the valve access door area.