PR CONVERSION KIT BV-4604 CONTENTS:
ITEM | QTY | PART NUMBER |
| ITEM DESCRIPTION |
|
|
|
| |
Regulator | 1 |
| SIT 820 NOVA mV Gas Valve | |
Pilot Orifice | 1 | #35 Pilot Injector Orifice | ||
Front Spud Orifice | 1 | 69 | DMS LP Front Orifice Spud | |
Middle Spud Orifice | 1 | 55 | DMS LP Middle Orifice Spud | |
Rear Spud Orifice | 1 | 53 | DMS LP Rear Orifice Spud | |
Conversion Label | 1 | Conversion NG to LP | ||
Instructions | 1 | Conversion Kit Instructions |
PR CONVERSION KIT BV-3004 CONTENTS:
ITEM | QTY | PART NUMBER |
| ITEM DESCRIPTION |
|
|
|
| |
Regulator | 1 | SIT 820 NOVA mV Gas Valve | ||
Pilot | 1 | #35 Pilot Injector Orifice | ||
Front Spud Orifice | 1 | 70 | DMS LP Front Orifice Spud | |
Middle Spud Orifice | 1 | 59 | DMS LP Middle Orifice Spud | |
Rear Spud Orifice | 1 | 55 | DMS LP Rear Orifice Spud | |
Middle Burner | 1 | Middle Burner for 30,000Btu | ||
Rear Burner | 1 | Rear Burner for 30,000Btu | ||
Conversion Label | 1 | Conversion NG to LP | ||
Instructions | 1 | Conversion Kit Instructions |
NG CONVERSION KIT BV-4603 CONTENTS:
ITEM | QTY | PART NUMBER |
| ITEM DESCRIPTION |
|
|
|
| |
Regulator | 1 |
| SIT 820 NOVA mV Gas Valve | |
Pilot | 1 | #51 Pilot Injector Orifice | ||
Front Spud Orifice | 1 | 55 | DMS NG Front Orifice Spud | |
Middle Spud Orifice | 1 | 45 | DMS NG Middle Orifice Spud | |
Rear Spud Orifice | 1 | 40 | DMS NG Rear Orifice Spud | |
Conversion Label | 1 | Conversion LP to NG | ||
Instructions | 1 | Conversion Kit Instructions |
NG CONVERSION KIT BV-3003 CONTENTS:
ITEM | QTY | PART NUMBER |
| ITEM DESCRIPTION |
|
|
|
| |
Regulator | 1 | SIT 820 NOVA mV Gas Valve | ||
Pilot | 1 | #51 Pilot Injector Orifice | ||
Front Spud Orifice | 1 | 57 | DMS NG Front Orifice Spud | |
Middle Spud Orifice | 1 | 50 | DMS NG Middle Orifice Spud | |
Rear Spud Orifice | 1 | 45 | DMS NG Rear Orifice Spud | |
Middle Burner | 1 | Middle Burner for 30,000Btu | ||
Rear Burner | 1 | Rear Burner for 30,000Btu | ||
Conversion Label | 1 | Conversion LP to NG | ||
Instructions | 1 | BV4650 | Conversion Kit Instructions |
NOTE: Conversion kits are available only for natural gas and propane fuel.
NOTE: A Country Flame conversion kit is to be installed only by certified service technicians.
NOTE: Check kit contents for all parts. Do not attempt conversion with items missing.
NOTE: A Torx T20
NOTE: D.M.S. (DMS is Drill Manufacturer's Standard) Standard twist drill or steel wire gauge number. WARNING: The gas supply MUST BE SHUT OFF prior to disconnecting the electrical power and
| before proceeding with ANY conversion kit installation. |
Version 1.0h | 14 |