CHECK FLAME AND PILOT
FREQUENCY: Periodically.
PERFORMED BY: Qualified service technician or homeowner.
TASK PERFORMED: Visually inspect the three burner’s flame height and burn patterns. The front burner flame will be barely visible through the glowing embers. The middle and back burner flames are steady and not lifting or floating from away from the burner surfaces. Refer to FIGURE 5d for a picture representation of the proper flame with logs and embers installed. Visually inspect that the pilot light is burning with four blue flame nodes, FIGURE 21, protruding from the pilot flame diffuser, FIGURE 21, Item B. There should be no sputter or blockage of any of the pilot flame or its four flame nodes. There should be a blue flame surrounding the outside edge of the pilot flame diffuser, FIGURE 21, Item B. In the event any abnormality is observed in the burner flame pattern or the pilot light flame pattern, contact a local authorized Country Flame Dealer or certified technician.
FIGURE 21: STANDING PILOT
WARNING: DO NOT ATTEMPT TO CLEAN GLASS UNTIL APPLIANCE IS COOL
GLASS CLEANING
FREQUENCY: Before the first use and after first four hours of use the glass should be cleaned; thereafter, clean as necessary.
PERFORMED BY: Homeowner.
TASK PERFORMED: Remove the door assembly by unhooking the four locks (2 locks on each side). Use a household glass cleaner or a Hearth Industry approved gas stove glass cleaner. Replace the door assembly and close the four locks to properly seal the door to the body of the Bayvue DV.
WARNING: DO NOT USE ABRASIVE CLEANERS ON GLASS SURFACE
CHECK VENT SYSTEM
FREQUENCY: Once during annual inspection. See General Inspection for additional requirements.
PERFORMED BY: Qualified service technician or homeowner.
TASK PERFORMED: Check complete vent system for corrosion, moisture problems, pin holes or broken seals. Remove chimney cap and inspect vent and cap for debris. Ensure clean and open vent system.
Version 1.0h | 33 |