STEP 14 Open the gas supply and perform gas leak test. One of the best methods used to check for gas leaks is soap bubbles. Soap bubbles are made by mixing liquid detergent with a little water and shaking vigorously to create soap bubbles. Cover the gas pipe joint or valve component with these soap bubbles. If soap bubbles grow in size or the bubbles are blown off the connection, a gas leak exists. Make necessary repairs and retest until no change in soap bubbles is seen at any joint or valve connection.

WARNING: DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS

STEP 15 Re-light the appliance. Check the flame control operation.

NATURAL GAS CONVERSION

Conversion from propane to natural gas follows the same 15 steps listed above using the parts from a natural gas conversion kit. Adhere to the following:

NOTE: Conversion kits are to be installed by qualified service technicians.

NOTE: Do not install a kit IF conversion items are missing; check kit for all parts needed.

NOTE: A Torx T20 Tamper-Proof screwdriver may be ordered separately if needed.

INTAKE AND EXHAUST CONDITIONS

WARNING: (Safety relief valves) Operation of this appliance with an improperly installed or an improperly maintained venting system could result in carbon monoxide poisoning. Make sure that all safety relief valves are closed and free from obstruction at all times. This is crucial in terms of operational safety. IT IS STRONGLY RECOMMENDED THAT A CARBON MONOXIDE DETECTOR BE PLACED IN THE VACINITY OF THIS PRODUCT TO ENSURE MAXIMUM SAFETY. IF BATTERY OPERATED DETECTORS ARE USED, REPLACE THE BATTERY ANNUALY.

SEALED VENTING SYSTEM

The Bayvue DV is designed for a sealed vent system. This means that all flue connections, including all seams and joints, are to be sealed with high temperature silicone rated for a minimum of 600OF (316OC) to ensure that a proper draft occurs during appliance operation. If it becomes necessary to disassemble the venting, proper care must be used to reassemble and reseal the vent air intake assembly.

THERMOSTAT/FAN CIRCUIT

The Bayvue DV is pre-wired to accept a millivolt wall thermostat and includes as standard, a room air blower fan assembly. This blower is equipped with a three-prong 120 VAC grounded power cord that protects against shock hazard. This plug should be connected directly into a properly grounded three- prong receptacle. Do not cut or remove the grounding pin from the blower’s plug.

The room air blower fan system is activated once the power cord explained in the preceding paragraph has been plugged in. The fan circuit is activated along with the heat sensing thermo-disc and the fan speed control rheostat. A wall thermostat can be connected to the terminal block on the back of the pedestal. Simply remove the factory installed jumper and wire in the thermostat. Refer to FIGURE 12. CAUTION: Label all wires prior to disconnection when servicing the controls or the blower system. Wiring errors can cause improper and dangerous operational conditions. ALWAYS verify proper operation of the Bayvue DV product after any servicing. Should any problems or operational issues be noted after servicing has been completed, DO NOT USE THE SYSTEM until corrections have been made.