FIGURE 12: BLOWER FAN
FAN INSTALLATION
The Bayvue DV comes standard with the fan kit installed. The Fan Kit consists of a blower system. The fan is connected to the Bayvue DV’s wiring harness. The Bayvue DV is pre-wired for and includes a rheostat (speed control), a heat activated thermo-disc and a 120 volt receptacle. The fan slips inside the back of the pedestal into two slides mounted to the bottom of the firebox.
DIRECT VENT INSTALLATION
GENERAL
Country Flame Bayvue DV product is approved for side wall vent or vertical vent through a roof. Only Simpson Dura Vent chimney components or Selkirk Model Direct-Temp chimney components may be used with this product. Simpson Dura Vent chimney vent products are listed in this manual to assist with vent installation selection. Read all these instructions carefully before starting the installation. Failure to follow instructions may create a fire or other safety hazard, and will void the product warranty. Be sure to follow installation instructions and maintain proper venting and maintain clearances to combustible that will vary from one installation to another.