Craftsman 139.53626SR - I/2HP, 139.53515SR - I/2HP Operation of Your Opener, Care Of The Opener

Models: 139.53626SR - I/2HP 139.53515SR - I/2HP

1 24
Download 24 pages 10.04 Kb
Page 3
Image 3
Operation of Your Opener

Operation of Your Opener

CAUTION

BEFORE YOU PROCEED, PLEASE READ THE SAFETY RULES ON PAGE 2 AND OPERATING INSTRUCTIONS ON THIS PAGE CAREFULLY.

TO AVOID DIFFICULTY DURING INSTALLATION, DO NOT RUN OPENER UNTIL INSTRUCTED TO DO SO.

USING THE OPENER

Your opener can be activated by any of the following devices:

1.The 3_Function Transmitter. Hold LARGE push button down until the door starts to move.

2.The Wall Control. Hold push bar down until the door starts to move.

3, The Key Switch or Touch Code Transmitter accessories.

Described on page 4.

OPENING THE DOOR MANUALLY

THE DOOR SHOULD BE FULLYCLOSEDIF POSSIBLE. WEAKOR

BROKEN SPRINGS COULD ALLOW AN OPEN DOOR TO FALL RAPIDLY.PROPERTY DAMAGEOR SERIOUS PERSONALINJURY COULD RESULT. DO NOT USE EMERGENCY HANDLE TO PULL DOOR OPEN OR CLOSED.

The door can be operated manually by disconnecting it from the opener. Pull down sharply on the red emergency release handle and lift the door manually. To automatically reconnect the door to the opener, press the Wait Control push bar.

LOCKOUT FEATURE: prevents trolley from reconnecting automatically. If you need to use this feature, pull emergency handle down and back (toward the opener). Trolleywill remain "Locked-Out" and door can be raised and lowered manually.

To reconnect trolley, pull emergency handle straight down.

DO NOT PERMIT CHILDREN TO PLAY IN DOOR AREA.

OPERATE ONLY WHEN OPENER IS PROPERLY

ADJUSTED AND THE DOOR IS VISIBLE AND

UNOBSTRUCTED.

WHEN OPENER IS ACTIVATED:

1.If open, the door will close. If closed, the door will open.

2.If closing, the door will reverse.

3.If opening, the door will stop (allowing space for entry and exit of pets and for fresh air).

4.If the door has been stopped in a partially open position, it will close.

5.If an obstruction is encountered while closing, the door will reverse.

6.If an obstruction is encountered while opening, the door will stop.

7.If the optional 'Infrared Sensor' is installed, the garage door will reverse in the closing cycle when the invisible beam is broken. An open door will not close when beam is broken. The sensor has no effect in the opening cycle.

OPENER LIGHTS will turn on under the following conditions: when the opener is initially plugged in; when the power is interrupted; when the opener is activated. They will turn off automatically after 41/2 minutes or provide constant light when Light Feature is activated. Bulb size 75 watts maximum.

CARE OF THE OPENER

When properly installed, opener will provide high performance

CHAIN TENSION ADJUSTMENT: After installation of the

with a minimum of maintenance. The opener does not require additional lubrication.

Most complaints of unsatisfactory opener operation can be traced to problems with the door itself. When operated manually, a properly balanced door will stay in any point of travel while being supported entirely by its springs.

THE OPENER IS NOT INTENDED TO CORRECT ANY PROBLEMS THAT ARE CAUSED BY AN UNBALANCED OR

BINDING DOOR, BROKEN DOOR SPRINGS OR BY FAULTY DOOR HARDWARE.

LIMIT AND FORCE ADJUSTMENTS: These adjustments must be checked and properly set when opener is installed. Only a screwdriver is required. Page 17 refers to the limit and force adjustments. Follow instructions carefully.

REPEAT SAFETY REVERSE TEST AFTER ANY ADJUST- MENT OF FORCE AND/OR LIMITS. Weather conditions

may cause some minor changes in door operation requir- ing some readjustments, particularly during the first year of operation.

THE SAFETY REVERSE SYSTEM IS IMPORTANT (See pg. 18). GARAGE DOOR MUST REVERSE ON CONTACT

WITH A ONE-INCH OBSTACLE PLACED ON THE FLOOR. FAILURE TO PROPERLY ADJUST OPENER MAY RESULT

IN SERIOUS PERSONAL INJURY FROM A CLOSING GA R._.GE DOOR.

MAINTENANCE

AT LEAST 4 TIMES A YEAR

MANUALLY OPERATE DOOR. If it is unbalanced or binding, call for professional garage door service.

CHECK TO BE SURE DOOR OPENS & CLOSES FULLY. Adjust Limits and/or Force if necessary.

REPEAT SAFETY REVERSE TEST. Make any necessary adjustments (see page 18).

opener and adjustment of forces and limits, the chain may appear loose. This is normal, To check the chain tension: disconnect the trolley by pulling the red emergency handle. If the chain returns to the position described and illustrated in Step 5 page 9, DO NOT make ANY further adjustments.

TRANSMITTER: The 3-function transmitter will operate more than one garage door opener, if desired. The other push but- tons may also be used to operate 53000 and 53000SR Series tight controls. Transmitter may be secured to car sun visor with clip provided. Additional transmitters can be purchased at any time. Refer to Accessories on page 4.

Any new transmitters must be set to the same code as the original transmitter. Page 19 explains how to change your existing code and use the transmitter(s) with other 53000 and 53000 SR receivers. Self service of your radio controls is not

recommended. If service is needed, contact your nearest

Sears Service Center.

TRANSMITTER BATTERY: The 12 Volt battery should produce power for at least one year. As long as the battery power is adequate, the transmitter test light will glow when the push button is pressed (and the opener will Operate). When the light does not come on, replace the battery. If trans- mission range lessens, check battery test light.

TO CHANGE BATTERY." Slide the battery compartment cover down. Position new 12 Volt battery as directed.

OF YOUR OPENER

TWICE A YEAR

CHECK CHAIN TENSlON. Adjustifnecessa_

ONCE A YEAR

OIL DOOR ROLLERS, BEARINGS AND HINGES.

3

Page 3
Image 3
Craftsman 139.53626SR - I/2HP Operation of Your Opener, Care Of The Opener, Operate Only When Opener Is Properly