0nstatUation
STEP 8 ConnectElectricPower
I
TO AVOID SERIOUS PERSONAL INJURY FROM ENTANGLEMENT, REMOVE ALL ROPES CON NECTEDTO THE I GARAGE DOOR BEFORE OPERATING DOOR OPENER_
REMOVE EXISTING GARAGE DOOR LOCKS OR USE A WOOD SCREW OR NAIL TO MAKE THE_,_ INOPERATIVE, INSTALLATION AND WIRING MUST BE IN COMPLIANCE WITH LOCAL BUILDING AND ELECTRICAL CODES. OPERATION AT OTHER THAN !2OV 6OHz WILL CAUSE OPENER MALFUNCTION AND DAMAGE,
IF LOCAL ELECTRICAL CODES DO NOT REQUI RE PER MAN ENT WIRING: Insert the
IF LOCAL CODES REQUIRE PERMANENTWIRING: Refer to illustration,
PROCEDURE: Make connection through 7/8 inch diameter hole in top of opener chassis,
1o Remove opener chassis cover by removing the 4 cover screws,
2,, Remove attached
3.Connect black (line) wire to black wire on terminal block; white (neutral) wire to white terminal wire; green (ground) wire to green ground screw
CAUTION: BE SURE UNIT IS GROUNDED
ACCORDING TO LOCAL CODE
Ground Tab
Ground Screw
I Wire
_,White Wire
STEP 9 i. to, Lights andLenses
PROCEDURE: Install a 75 watt maximum light bulb in each socket as shown The lights turn on automatF calty when opener starts. After
IMPORTANT NOTE: If the lights in your garage door opener do not work, it may NOT be the fault of
the opener° Some
base tab. Use standard.neck bulbs°
Lens Tab
INSTALLING LENSES: Slide lenses into the fens guides as shown. Snap bottom tabs into lens slots. (The force and limit adjustment settings are located on side panels behind lenses),
NOTE: FOR CONVENIENCE, LENSES MAY BE IN-
STALLED AFTER ADJUSTMENT, STEP 3, PAGE 20_
Lens Slot
Lens Guide
15