AFTER EACH USE
Water should not remain in the unit for long periods of time. Sediments or minerals can deposit on pump parts and "freeze" pump action. Follow these procedures after every use:
1.Flush detergent siphoning tube by placing filter into a pail of clean water while running pressure washer in low pressure mode (adjustable nozzle in forward position). Flush for one to two minutes.
2.Shut off engine, let it cool, then remove all hoses.
3.Disconnect spark plug wire from spark plug.
4.Empty pump of all liquids by pulling recoil handle about 6 times. This should remove most liquid in pump.
5.if storing for more than 30 days see "Long Term Storage" on next page.
6.Coil high pressure hose and inspect it for damage. Cuts in hose or fraying could result in leaks and loss of pressure. Should any damage be found, replace hose. DO NOT attempt to repair a damaged hose. Replace hose with genuine Sears part.
7.Disconnect hose from spray gun and high pressure outlet on pump. Drain water from hose, gun, and nozzle extension. Use a rag to wipe off the hose.
8.Coil hose and properly hang it on wire support provided.
9.Reconnect spark plug wire to spark plug.
10.Store unit in a clean, dry area.
WARNING! NEVER store the engine with fuel in the gas tank indoors or in enclosed, poorly ventilated areas where fumes may reach an open flame, a spark, or pilot light.
WINTER STORAGE
CAUTION
*Failure to do so will permanently damage your pump and render your unit inoperable,
,Freeze damage is not covered under warranty.
To protect the unBtfrom freezing temperatures:
1.Flush detergent siphoning tube by placing filter into a pail of clean water while running pressure washer in low pressure mode (adjustable nozzle in forward position). Flush for one to two minutes.
2.Empty pump of all pumped liquids by pulling recoil handle about 6 times. This should remove most
liquid in pump.
3.Use pump saver, available at Sears retail item
4.If pump saver is not available, connect a
18