5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve by turning clockwise. The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "Off".

2.Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Risk of Bursting. Too much air

pressure causes a hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place.

The compressor is ready for use.