14-ENG
A10819
5. Run the compressor for 15
minutes. Make sure the drain
valve is open and there is minimal
air pressure build-up in tank.
6. After 15 minutes, close the drain
valve by turning clockwise. The
air receiver will fill to "cut-out"
pressure and the motor will stop.
The compressor is now ready for use.
Before Each Start-Up:
1. Place On/Auto/Off lever to "Off".
2. Pull the regulator knob out and
turn counterclockwise to set the
outlet pressure to zero.
3. Attach hose and accessories.
NOTE: The hose or accessory
will require a quick connect plug
if the air outlet is equipped with a
quick connect socket.
Risk of Bursting.
Too much air
pressure causes a hazardous
risk of bursting. Check the
manufacturer’s maximum pressure
rating for air tools and accessories.
The regulator outlet pressure
must never exceed the maximum
pressure rating.
How to Start:
1. Turn the On/Auto/Off lever
to "On/Auto" and allow tank
pressure to build. Motor will
stop when tank pressure reaches
"cut-out" pressure.
2. Pull the regulator knob out
and turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place.
The compressor is ready for use.