To Replace Regulator

1.Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.

2.Set the On/Auto/Off lever to "Off" and unplug unit.

3.Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.

 

Outlet

 

Pressure

 

Gauge

Regulator

Quick

Connect

 

4. Remove the regulator.

5. Apply pipe sealant tape to the nipple.

Nipple

6.Assemble the regulator and orient as shown.

Regulator

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

Regulator

Arrow

7. Reapply pipe sealant to outlet pressure gauge and quick connect.

8. Reassemble outlet pressure gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.

A10819

18- ENG