To Add Oil
Drain tank to release air pressure
before removing the oil fill cap or oil drain plug.
1.Place unit on a level surface.
2.Remove oil fill plug (A) and slowly add compressor oil until it is even with the top of the oil fill hole. NOTE: Do not allow oil to be lower than 3/8" (6 threads) from the top at any time. When filling the crankcase, the oil flows very slowly into the pump. If the oil is added too quickly, it will overflow and appear to be full.
NOTE: Crankcase oil capacity is approximately 16 fluid ounces.
3.Replace oil fill plug.
A
INSTALLATION
Location of the Air Compressor
Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.
GROUNDING INSTRUCTIONS
RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.
The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.
1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.
IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.
2.Make sure the outlet being used has the same configuration
as the grounded plug. DO NOT USE AN ADAPTER. See illustration.
Plug
Grounding Pin
Grounded Outlets
A09713 | 12- ENG |