Clean Pre-Cleaner and Air Cleaner Cartridge

Your engine is equipped with an oval dual element air cleaner: the two elements include a foam pre-cleaner and an air cleaner cartridge.

To remove the air cleaner element, loosen two cover screws and lift cover. Carefully remove foam pre- cleaner and air cleaner cartridge.

To clean pre-cleaner and air cleaner cartridge, wash in liquid detergent and water. Allow to dry thoroughly before using. Do not oil the precleaner or cartridge. Replace if very dirty or damaged.

After cleaning the pre-cleaner and air cleaner cartridge, replace pre-cleaner on air cleaner car- tridge.

Install air cleaner assembly (pre-cleaner and cartridge) in base. Then install cover on air cleaner and tighten screws securely to base.

COVER

2 SCREWS

PRE-CLEANERCARTRIDGE

BASE

NOTE: Do not use petroleum solvents, e.g., kerosene, which will cause the cartridge to deteriorate. Do not use pressurized air to clean cartridge. Pressurized air can damage the cartridge.

Clean and Replace Spark Plug

Change the spark plug every 100 hours of operation or once each year, whichever comes first. This will help your engine to start easier and run better.

.030” (0.76 MM)

WIRE GAGE

RESISTOR

SERVICE AND ADJUSTMENTS

Carburetor

The carburetor of your high pressure washer is pre-set at the factory. The carburetor should not be tampered with. If your pressure washer is used at an altitude in excess of 5000 feet consult with your nearest Sears Service Center regarding high altitude set changes.

Engine speed was properly adjusted at the factory and should

require no additional adjustment. Do not attempt to change engine speed. If you believe the engine is running too fast or too slow, take your pressure to a Sears Authorized Service Center for repair and ad- justment.

High engine speeds are dangerous and increase the risk of personal

injury or damage to equipment.

Low engine speeds impose a heavy load on the engine and

could shorten engine life.

Nozzle Cleaning

If the nozzle becomes clogged with foreign materials, such as dirt, excessive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pulsate. Clean the nozzle immedi- ately using the nozzle kit supplied and the following instructions.

1.Shut off the pressure washer and turn off the water supply.

2.Disconnect spark plug wire.

13

Page 13
Image 13
Craftsman MGP-769010 Service and Adjustments, Clean Pre-Cleaner and Air Cleaner Cartridge, Clean and Replace Spark Plug