b wire gauge
CCTM owner’s manual
stranded cable length
2meters
5meters
10meters
30meters
wire gauge |
|
| power loss | |
|
| 8 Ω load | 4 Ω load | 2 Ω load |
| 0.3mm2 | 2.9% | 5.6% | 10.8% |
| 0.5 | 1.74 | 3.4 | 6.7 |
| 0.75 | 1.16 | 2.3 | 4.5 |
| 1.5 | 0.58 | 1.16 | 2.3 |
| 2.5 | 0.35 | 0.70 | 1.39 |
| 4.0 | 0.22 | 0.44 | 0.87 |
| 0.5mm2 | 4.3% | 8.2% | 15.5% |
0.75 | 2.9 | 5.6 | 10.8 | |
1.5 | 1.45 | 2.9 | 5.6 | |
2.5 | 0.87 | 1.74 | 3.4 | |
4 | 0.55 | 1.09 | 2.2 | |
6 | 0.37 | 0.73 | 1.45 | |
|
|
|
|
|
| 0.5mm2 | 8.24% | 5.5% | 28% |
| 0.75 | 5.6 | 10.8 | 19.9 |
| 1.5 | 2.9 | 5.6 | 10.8 |
| 2.5 | 1.74 | 2.9 | 6.7 |
| 4 | 1.09 | 1.74 | 4.3 |
| 6 | 0.73 | 1.09 | 2.9 |
|
|
|
|
|
| 0.75mm2 | 15.5% | 0.73% | 45% |
1.5 | 8.2 | 15.5 | 28 | |
2.5 | 5.1 | 9.8 | 18.2 | |
4 | 3.2 | 6.3 | 12.0 | |
6 | 2.2 | 4.3 | 8.2 | |
10 | 1.31 | 2.6 | 5.1 |
stranded cable length | wire gauge |
|
| power loss | ||
|
| 8 Ω load | 4 Ω load | 2 Ω load | ||
|
|
|
| |||
| 5feet |
| 18AWG | 0.81% | 1.61% | 3.2% |
|
|
| 16 | 0.51 | 1.02 | 2.0 |
|
|
| 14 | 0.32 | 0.64 | 1.28 |
|
|
| 12 | 0.20 | 0.40 | 0.80 |
|
|
| 10 | 0.128 | 0.25 | 0.51 |
|
|
|
|
|
|
|
| 10feet |
| 18AWG | 1.61% | 3.2% | 6.2% |
|
| 16 | 1.02 | 2.0 | 4.0 | |
|
| 14 | 0.64 | 1.28 | 2.5 | |
|
| 12 | 0.40 | 0.80 | 1.60 | |
|
| 10 | 0.25 | 0.51 | 1.01 | |
|
|
|
|
|
|
|
| 40feet |
| 18AWG | 6.2% | 11.9% | 22% |
|
|
| 16 | 4.0 | 7.7 | 14.6 |
|
|
| 14 | 2.5 | 5.0 | 9.6 |
|
|
| 12 | 1.60 | 3.2 | 6.2 |
|
|
| 10 | 1.01 | 2.0 | 4.0 |
|
|
| 8 | 0.60 | 1.20 | 2.4 |
|
|
|
|
|
|
|
| 80feet |
| 18AWG | 11.9% | 22% | 37% |
|
| 16 | 7.7 | 14.6 | 26 | |
|
| 14 | 5.0 | 9.6 | 17.8 | |
|
| 12 | 3.2 | 6.2 | 11.8 | |
|
| 10 | 2.0 | 4.0 | 7.7 | |
|
| 8 | 1.20 | 2.4 | 4.7 |