LIGHTING INSTRUCTIONS FOR BOILERS EQUIPPED WITH HONEYWELL

LIGHTING INSTRUCTIONS FOR BOILERS EQUIPPED WITH HONEYWELL

VR8200 AND VR8300 SERIES GAS VALVES (STANDING PILOT)

VR8200 AND VR8300 SERIES GAS VALVES (STANDING PILOT) FOR YOUR SAFETY READ BEFORE OPERATING  FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

LIGHTING INSTRUCTIONS If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.Remove front access panel.

5.Rotate the gas control knob clockwise TO TURN OFF GAS TO APPLIANCE to OFF.

8.

Turn Knob on gas control counterclockwise

 

to “PILOT”.

 

9.

Push down and hold the red reset button while

 

you light pilot burner with a match.

 

After about one minute, release reset button.

 

Pilot should remain lit. If it goes out, turn gas

 

control knob clockwise

to OFF. To relight,

 

repeat steps 5-9.

 

 

If button does not pop up when released, stop

GAS OUTLET

RESET BUTTON

GAS INLET

and immediately call your service technician

or gas supplier.

If the pilot will not stay lit after several tries,

turn the gas control knob to “OFF” and call

your service technician or gas supplier.

GAS CONTROL KNOB (SHOWN IN “ON” POSITION)

GAS VALVE - TOP VIEW

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow “B” in the safety inform- ation above on this label. If you don’t smell gas, go to the next step.

7.Find pilot - follow metal pilot

tube from gas control to

 

 

pilot burner.

PILOT

THERMO-

 

BURNER

COUPLE

10.After pilot remains lit when red reset button is released, turn gas control knob counterclockwise 3029 to ON.

11.Replace front access panel.

12.Turn on all electric power to the appliance.

13.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the appliance if service is to be performed.

3.Push in gas control knob slightly and turn

clockwise Manual background to “OFF”. Do not Force.

146-80-254 Rev. 0 (Standing Pilot)

3029

Page 30
Image 30
Crown Boiler CWI379 For Your Safety Read Before Operating, Lighting Instructions, To Turn Off Gas To Appliance, 3029