CPEx | CyberResearch® CPU Cards |
The ALi M5283 is a highly integrated disk drive controller that is capable of managing Parallel- ATA and
You must properly configure the associated BIOS settings before the Ctlr+A key combination can take effect. Please refer to Chapter 4 Award BIOS Setup, the discussions of the associated configurations for more details. SATA disk drive support must be initiated under the following two BIOS sub- menus.
1.BootYou will not be able to access the ALi configuration utility unless you have properly initiated the SATA disk drive support in the Award BIOS configuration utility.
CAUTION!
A configured RAID volume (which may consist of multiple hard drives) appears to an operating system as a contiguous storage space. Your operating system will not be able to distinguish the physical disk drives contained in a RAID configuration.
1.1.2 Precautions:1.One key benefit a RAID configuration brings you is that a single hard drive can fail within a RAID array without damaging your data. With RAID1 array, you can replace a failed drive and restore your RAID configuration.
However, if you replace the wrong drive when you are trying to remove a failed one, irrecoverable data loss will occur! It is therefore strongly recommended to mark the physical connections of all of your SATA disk drives. If a drive member of a RAID array should fail, you will then be able to correctly locate a failed drive.
80 | ©Copyright 2007 CyberResearch, Inc. |