Label

Description

unit_name

Identifies the board. The parameter should not exceed 20 characters.

prompt

Specifies the prompt to be used by the virtual console. It should not exceed 40

 

characters.

escape_char

Specifies the escape key to be used by the virtual console. It should not exceed one

 

character. If the value begins with 0x it is assumed to be in hexadecimal. The <ESC> key

 

has the value 0x1b.

shortcut_char

Specifies the shortcut key to be used by the virtual console. It should not exceed one

 

character. If the value begins with 0x it is assumed to be in hexadecimal. The value 0x0

 

turns this feature off.

username

Defines the administrator's login name -- maximum 19 characters.

password

Sets the administrator's password -- maximum 19 characters.

syslog

Enables the system log and determines which messages will be displayed. The possible

 

values for each of the three parameters are disabled or enabled (first parameter), line,

 

debug, user, system, modem or a combination of them using “” (second parameter) and

 

sys, alert, critical, error, warning, normal, info or dbg (third parameter). A space

 

should appear between each of the three parameters, but not within a parameter.

dsps_auto_restart

On occasion, the line requests that the DSP re-load its configuration. Sometimes the re-

 

load is not successful and the DSP must try many times. This parameter determines the

 

number of times the DSP may try to re-load its configuration. The values range from 0

 

(infinite number of retries) to 255.

 

FIG 4.1 GENERAL PARAMETERS

Chapter 4 Board and System Configuration

15

Page 15
Image 15
Cyclades PC400 installation manual Label Description