Parameter

Description

Value for T1

Value for E1

 

 

line

line

rx_sensitivity

Sensitivity for reception.

shaul

shaul

companding_mode

There are two options each for T1 and E1 lines. Ask

ulaw

alaw

 

the service provider.

 

 

signaling_type

Applies when CAS signaling mode is used. Ask the

loops

r2digital

 

service provider.

 

 

signaling_tone

Applies when CAS signaling mode is used. Ask the

mfr1

mfr2c

 

service provider.

 

 

country

Choose your country (cas only).

usa

brazil

interfn_1_begin

Logical link parameters

 

 

connection_type

Whether the interface will be used for dial-in, dial-out

both

both

 

or both.

 

 

phone_num

Phone number assigned to channel, if any.

none

301

dsp_profile_id

Number that identifies the profile, defined elsewhere

1

1

 

(or default)

 

 

interfn_1_end

End of logical link parameters

 

 

∙∙∙

 

 

 

 

 

 

 

interf1_end

End of first interface parameters

 

 

interf2_begin

Second interface parameters

 

 

∙∙∙

 

 

 

 

 

 

 

interf2_end

End of second interface parameters

 

 

dsps_auto_restart

The number of times the DSP should try to re-load

0

0

 

its configuration if requested.

 

 

 

FIGURE 4.8 RAS DIAL-IN APPLICATION PARAMETERS (CONT.)

 

Chapter 4 Board and System Configuration

24

Page 24
Image 24
Cyclades PC400 installation manual ∙∙∙