Cyclades PC400 installation manual Parameter Description Value for T1 Value for E1 Line

Models: PC400

1 45
Download 45 pages 58.97 Kb
Page 23
Image 23

Parameter

Description

Value for T1

Value for E1

 

 

line

line

unit_name

Name used to identify the board.

PC400

PC400

prompt

Can be changed to identify which board is being

Select option

Select option

 

accessed.

==>

==>

escape_char

0x1b is the <ESC> key.

0x1b

0x1b

shortcut_char

0x0 turns this feature off.

0x0

0x0

username

Login name for administrator.

super

super

password

Password for administrator

supc

supc

syslog

Enables syslog messages indicated.

enabled

enabled

 

 

linedebugusers

linedebugusers

 

 

ystemmodem

ystemmodem

 

 

info

info

interf1_begin

First interface parameters

 

 

interf_type

Indicates line time

t1

e1

clock_mode

Normally slave.

slave

slave

line_code

There are two options each for T1 and E1 lines. Ask

b8zs

hdb3

 

the service provider.

 

 

frame_mode

There are several data framing options for both T1

esf

crc4

 

and E1.

 

 

line_build_out

Applies only to T1 lines. Ask the service provider.

0db

 

 

 

 

 

signaling_mode

Can be pri (ISDN), cas or none.

cas

cas

FIGURE 4.8 RAS DIAL-IN APPLICATION PARAMETERS

Chapter 4 Board and System Configuration

23

Page 23
Image 23
Cyclades PC400 installation manual Parameter Description Value for T1 Value for E1 Line, RAS DIAL-IN Application Parameters