onhook_timer

Valid only for CAS in Brazil. Valid values are 20-255, in units of a fraction of a second.

 

When the PC400 answers an incoming call it waits for the period defined by

 

answer2_timer, then it hangs up. Next, it waits the period defined by onhook_timer and

 

reconnects. The line remains active if the call was not a collect call. This is necessary

 

because in Brazil a collect call is accepted by simply remaining on the line.

answer2_timer

Valid only for CAS in Brazil. Specifies the time that should elapse before answering an

 

incoming call. Valid values are 15-255, in units of a fraction of a second. See

 

description of onhook_timer.

trunk_number

Principal phone number assigned to the ISDN trunk line. Use the value none for this

 

parameter if the incoming number should not be confirmed by the PC400. This is

 

recommended when the provider does not send the trunk line number in the incoming

 

call message. The value should not exceed 30 characters.

switch_type

Switch type when PRI signaling is used. au1 (for Australia), ets (for Europe ETSI), vn6

 

(for France), tr6 (for Germany), dms (for USA – NorTel DMS-100), 5ess (for USA – AT&T

 

Custom), ntt (for Japan), n_isdn2 (for USA – NI-2), hkt (for Hong Kong) and 4ess (for

 

USA – AT&T).

idle_timeout

For PRI signaling mode, specifies the idle timeout, in minutes, to drop one call. The

 

value should not exceed 127 and 0 indicates no timeout.

t200

For PRI signaling mode, specifies the ISDN T200 parameter, which may not exceed 255.

n200

For PRI signaling mode, specifies the ISDN N200 parameter, which may not exceed 255.

t203

For PRI signaling mode, specifies the ISDN T203 parameter, which may not exceed 255.

interf#_end

Marks the end of the configuration parameters for the first interface. See comments for

 

interf#_begin above.

 

FIG. 4.4 INTERFACE PARAMETERS (CONT.)