CY62146ESL MoBL®
Document #: 001-43142 Rev. ** Page 3 of 12
Maximum Ratings
Exceeding the maximum ratings may impair the useful life of the
device. These user guidelines are not tested.
Storage Temperature..................................–65°C to +150°C
Ambient Temperature with
Power Applied............................................ –55°C to +125°C
Supply Voltage to Ground Potential..................–0.5V to 6.0V
DC Voltage Applied to Outputs
in High-Z State[4, 5]...........................................–0.5V to 6.0V
DC Input Voltage[4, 5]........................................–0.5V to 6.0V
Output Current into Outputs (LOW).............................20 mA
Static Discharge Voltage............................................>2001V
(MIL-STD-883, Method 3015)
Latch up Current......................................................>200 mA
Operating Range
Device Range Ambient
Tempe ratur e VCC[6]
CY62146ESL Industrial –40°C to +85°C 2.2V–3.6V,
and
4.5V–5.5V
Electrical Characteristics
Over the Operating Range
Parameter Description Test Conditions
45 ns
UnitMin Typ [3] Max
VOH Output HIGH Voltage 2.2 < VCC < 2.7 IOH = –0.1 mA 2.0 V
2.7 < VCC < 3.6 IOH = –1.0 mA 2.4
4.5 < VCC < 5.5 IOH = –1.0 mA 2.4
VOL Output LOW Voltage 2.2 < VCC < 2.7 IOL = 0.1 mA 0.4 V
2.7 < VCC < 3.6 IOL = 2.1mA 0.4
4.5 < VCC < 5.5 IOL = 2.1mA 0.4
VIH Input HIGH Voltage 2.2 < VCC < 2.7 1.8 VCC + 0.3 V
2.7 < VCC < 3.6 2.2 VCC + 0.3
4.5 < VCC < 5.5 2.2 VCC + 0.5
VIL Input LOW Voltage 2.2 < VCC < 2.7 –0.3 0.6 V
2.7 < VCC < 3.6 –0.3 0.8
4.5 < VCC < 5.5 –0.5 0.8
IIX Input Leakage Current GND < VI < VCC –1 +1 μA
IOZ Output Leakage Current GND < VO < VCC, Output Disabled –1 +1 μA
ICC VCC Operating Supply
Current
f = fmax = 1/tRC VCC = VCCmax
IOUT = 0 mA, CMOS levels
15 20 mA
f = 1 MHz 2 2.5
ISB1 Automatic CE Power
down Current — CMOS
Inputs
CE > VCC 0.2V, VIN > VCC – 0.2V or VIN < 0.2V,
f = fmax (Address and Data Only),
f = 0 (OE, BHE, BLE and WE), VCC = VCC(max)
17μA
ISB2 Automatic CE Power
down Current — CMOS
Inputs
CE > VCC – 0.2V, VIN > VCC – 0.2V or VIN < 0.2V,
f = 0, VCC = VCC(max)
17μA
Notes
4. VIL(min) = –2.0V for pulse durations less than 20 ns.
5. VIH(max) = VCC + 0.75V for pulse durations less than 20 ns.
6. Full Device AC operation assumes a 100 μs ramp time from 0 to VCC (min) and 200 μs wait time after VCC stabilization.
[+] Feedback [+] Feedback